COPPER MOUNTAIN TECHNOLOGIES TR7530 CALIBRATION and COPPER MOUNTAIN TECHNOLOGIES TR7530 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the COPPER MOUNTAIN TECHNOLOGIES TR7530 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   COPPER MOUNTAIN TECHNOLOGIES TR7530   Description / Specification:    
COPPER MOUNTAIN TECHNOLOGIES TR7530 3 GHz Vector Network Analyzer, 75 ohm

The Copper Mountain TR7530 VNA is a 3 GHz, 75 ohm vector network analyzer designed for operation with an external PC. It connects to any Windows-based computer via USB and delivers accurate testing and measurement through a platform that can keep up with constant advancements as well as be remotely accessed.
Specifications.

Measured parameters: S11, S21.

Measurement Range.
Impedance: 75 Ω.
Test port connector: N-type, female:
Number of test ports: 2.
Frequency range: 20 kHz to 3.0 GHz.
Full CW frequency accuracy: ±5x10 -6.
Frequency setting resolution: 10 Hz.
Number of measurement points: 1 to 200,001.
Measurement bandwidth: 10 Hz to 30 kHz (with 1/1.5/2/3/5/7 steps).
Dynamic range (IF bandwidth 10 Hz):
  From 20 kHz to 300 kHz: 100 dB, typ. 110 dB,
  From 300 kHz to 3.0 GHz: 120 dB, typ. 123 dB.

Measurement Accuracy.
Accuracy of transmission measurements (magnitude / phase):
  +5 dB to +10 dB (0.65 dB / 3°),
  -50 dB to +5 dB (0.55 dB / 3°).
Accuracy of reflection measurements (magnitude / phase):
  -15 dB to 0 dB (0.4 dB / 3°),
  -25 dB to -15 dB (1.0 dB / 6°),
  -35 dB to -25 dB (3.0 dB / 20°).

Test Port Output.
Match (without system error correction): 22 dB.
Power range: 100 kHz to 6.0 GHz: -50 dBm to +5 dBm (-1 dBmV to 54 dBmV).
Power accuracy: ±1.0 dB.
Power resolution: 0.05 dB.
Harmonics distortion: -25 dBc.
Non-harmonic spurious: -30 dBc.

Test Port Intput.
Match (without system error correction): 22 dB.
Damage level: +23 dBm (71 dBmV).
Damage DC voltage: 35 V.
Noise level (defined as the rms value of the specified noise floor, IF bandwidth 10 Hz)
From 20 kHz to 300 kHz: -95 dBm.
From 300 kHz to 3.0 GHz: -115 dBm.

Measurement Speed.
Measurement time per point: 200 μs.
Source to receiver port switchover time: 10 ms.



 

Standard Calibration $730.00 *
*This is a Web introductory price for one calibration of the COPPER MOUNTAIN TECHNOLOGIES TR7530. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Spurious Signals
Spurious signals are undesired signals. They can be considered in two classes. They can be stationary; their frequency and amplitude do not change significantly, or non-stationary, where the frequency and/or amplitude change significantly over short time periods.


Please contact us for your COPPER MOUNTAIN TECHNOLOGIES TR7530 CALIBRATION and/or COPPER MOUNTAIN TECHNOLOGIES TR7530 3 GHz Vector Network Analyzer, 75 ohm REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: